Show Hamamatsu Avalanche Photo Diode 1403015248 - Archived data from Tue, 11. August 2020 17:58:28 CEST
This is all the information about APD 1403015248. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1403015248 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D15 |
Break-through voltage: | 418 V |
Voltage for Gain 100 (T=+25°C): | 390.8 V |
Dark current: | 12.2 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 308 |
Position in Box: | 5 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 363 |
Position in grid: | 16 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Nov 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 26. Oct 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 2 |
Bias voltage: | 390.8 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 391.2182534 V T = -25 °C: 354.8420997 V |
Voltage for Gain 150: | T = +20 °C: 399.2020178 V T = -25 °C: 362.4429025 V |
Voltage for Gain 200: | T = +20 °C: 403.639752 V T = -25 °C: 366.6987023 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.453999283 V-1 T = -25 °C: 4.88585889 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.663336489 V-1 T = -25 °C: 8.811878928 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.99805047 V-1 T = -25 °C: 15.47853835 V-1 |
Break-through voltage: | T = +20 °C: 418.1431328 V T = -25 °C: 381.374306 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:28:09 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:58:28 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:44:54 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:44:44 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:36:08 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:52 CET | jreher | Updated box and position via API. |
03. Nov 2017 16:13:01 CET | markus.moritz | Entered shipped after irradiation date. |
26. Oct 2017 16:36:09 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 11:34:21 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:07 CEST | Tobias | Assigned to grid via information extracted from APD DB. |