Show Hamamatsu Avalanche Photo Diode 1403015246 - Archived data from Fri, 05. February 2021 11:28:09 CET


This is all the information about APD 1403015246. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1403015246
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B12
Break-through voltage: 419 V
Voltage for Gain 100 (T=+25°C): 391.7 V
Dark current: 8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 308
Position in Box: 3
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 363
Position in grid: 14
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Nov 2017
Return for assembly: none
   
Irradiation:  
Date: 26. Oct 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 2
Bias voltage: 391.7 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 391.6499554 V     T = -25 °C: 355.3689787 V
Voltage for Gain 150: T = +20 °C: 399.5733739 V     T = -25 °C: 362.9597388 V
Voltage for Gain 200: T = +20 °C: 403.9664245 V     T = -25 °C: 367.2266607 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.321495299 V-1     T = -25 °C: 4.655316443 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.204246896 V-1     T = -25 °C: 9.248032956 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.32044129 V-1     T = -25 °C: 14.36824006 V-1
Break-through voltage: T = +20 °C: 417.8437615 V     T = -25 °C: 382.419908 V
   
Notes:


Version history

Time Author Change comment
19. May 2022 15:29:21 CEST oafedulidis Assigned to capsule by script
27. Aug 2021 11:10:48 CEST oafedulidis Updated box and position via API.
05. Feb 2021 11:28:09 CET jreher Updated box and position via API.
11. Aug 2020 17:58:28 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:44:53 CEST jreher Updated APD location via API.
21. Jul 2020 14:44:44 CEST jreher Updated box and position via API.
19. Dec 2019 16:36:08 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:18:52 CET jreher Updated box and position via API.
03. Nov 2017 16:13:01 CET markus.moritz Entered shipped after irradiation date.
26. Oct 2017 16:36:09 CEST markus.moritz Entered irradiation information.
29. Sep 2017 11:34:21 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:07 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:19 CEST Tobias Imported from Hamamatsu datasheet.