RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1402015170 - Archived data from Wed, 03. February 2021 18:19:25 CET


This is all the information about APD 1402015170. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1402015170
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G09
Break-through voltage: 426 V
Voltage for Gain 100 (T=+25°C): 397.1 V
Dark current: 5.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 42
Position in Box: 24
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 360
Position in grid: 2
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 397.577849 V     T = -25 °C: 360.8657067 V
Voltage for Gain 150: T = +20 °C: 405.4876358 V     T = -25 °C: 368.6070944 V
Voltage for Gain 200: T = +20 °C: 409.8278871 V     T = -25 °C: 372.9467158 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.371246769 V-1     T = -25 °C: 4.70021526 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.501923249 V-1     T = -25 °C: 9.170891063 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.55773014 V-1     T = -25 °C: 14.62712319 V-1
Break-through voltage: T = +20 °C: 425.5927438 V     T = -25 °C: 389.0158172 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:53:38 CET jreher Updated box and position via API.
03. Feb 2021 18:19:25 CET jreher Updated box and position via API.
11. Aug 2020 17:26:32 CEST jreher Updated APD characteristics via API.
27. Nov 2019 19:36:27 CET jreher Updated APD location via API.
25. Nov 2019 17:14:15 CET jreher Updated box and position via API.
04. Jul 2019 11:11:19 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:33 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:33:29 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 14:23:20 CET markus.moritz
29. Sep 2017 12:34:10 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:04 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:17 CEST Tobias Imported from Hamamatsu datasheet.