Show Hamamatsu Avalanche Photo Diode 1401015159 - Archived data from Tue, 11. August 2020 17:58:33 CEST
This is all the information about APD 1401015159. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1401015159 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E06 |
Break-through voltage: | 422 V |
Voltage for Gain 100 (T=+25°C): | 393.4 V |
Dark current: | 5.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 308 |
Position in Box: | 32 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 359 |
Position in grid: | 13 |
Arrival for irradiation: | 02. Nov 2017 |
Sent for analysis after irradiation: | 03. Nov 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 03. Nov 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 3 |
Bias voltage: | 393.4 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 394.2540154 V T = -25 °C: 357.7654786 V |
Voltage for Gain 150: | T = +20 °C: 402.162092 V T = -25 °C: 365.3385563 V |
Voltage for Gain 200: | T = +20 °C: 406.5473775 V T = -25 °C: 369.5871956 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.474534603 V-1 T = -25 °C: 4.892677448 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.784120066 V-1 T = -25 °C: 8.916419572 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.33623365 V-1 T = -25 °C: 15.69287358 V-1 |
Break-through voltage: | T = +20 °C: 422.1071435 V T = -25 °C: 385.3410045 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:28:12 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:58:33 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:44:55 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:44:46 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:36:31 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:54 CET | jreher | Updated box and position via API. |
03. Nov 2017 16:15:16 CET | markus.moritz | Entered shipped after irradiation date. |
03. Nov 2017 16:14:32 CET | markus.moritz | Entered irradiation information. |
02. Nov 2017 15:18:22 CET | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:04 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:31:16 CEST | Tobias | Imported from Hamamatsu datasheet. |