RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1401015142 - Archived data from Tue, 11. August 2020 17:58:31 CEST


This is all the information about APD 1401015142. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1401015142
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G07
Break-through voltage: 423 V
Voltage for Gain 100 (T=+25°C): 394.2 V
Dark current: 4.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 308
Position in Box: 19
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 358
Position in grid: 16
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 20. Oct 2017
Return for assembly: none
   
Irradiation:  
Date: 20. Oct 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 2
Bias voltage: 394.2 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 394.825801 V     T = -25 °C: 358.670908 V
Voltage for Gain 150: T = +20 °C: 402.7095435 V     T = -25 °C: 366.2795151 V
Voltage for Gain 200: T = +20 °C: 407.063799 V     T = -25 °C: 370.553181 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.644787318 V-1     T = -25 °C: 4.58041551 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.358756974 V-1     T = -25 °C: 9.020405146 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.62836938 V-1     T = -25 °C: 15.96081669 V-1
Break-through voltage: T = +20 °C: 422.6997393 V     T = -25 °C: 386.3692476 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:28:11 CET jreher Updated box and position via API.
11. Aug 2020 17:58:31 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:44:55 CEST jreher Updated APD location via API.
21. Jul 2020 14:44:45 CEST jreher Updated box and position via API.
19. Dec 2019 16:36:30 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:18:53 CET jreher Updated box and position via API.
20. Oct 2017 14:31:38 CEST markus.moritz Entered shipped after irradiation date.
20. Oct 2017 09:50:32 CEST markus.moritz Entered irradiation information.
29. Sep 2017 14:21:34 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:04 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:16 CEST Tobias Imported from Hamamatsu datasheet.