Show Hamamatsu Avalanche Photo Diode 1401015138 - Archived data from Tue, 11. August 2020 17:58:30 CEST
This is all the information about APD 1401015138. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1401015138 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D05 |
Break-through voltage: | 424 V |
Voltage for Gain 100 (T=+25°C): | 395.5 V |
Dark current: | 6.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 308 |
Position in Box: | 16 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 358 |
Position in grid: | 12 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 20. Oct 2017 |
Return for assembly: | none |
Irradiation: | |
Date: | 20. Oct 2017 |
Dose used: | 45 Gy |
Temperature: | 20 °C |
Position: | 2 |
Bias voltage: | 395.5 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 396.4321952 V T = -25 °C: 359.83711 V |
Voltage for Gain 150: | T = +20 °C: 404.2845914 V T = -25 °C: 367.4333335 V |
Voltage for Gain 200: | T = +20 °C: 408.636436 V T = -25 °C: 371.6847072 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.46718217 V-1 T = -25 °C: 4.867896979 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.79676047 V-1 T = -25 °C: 8.89465723 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.44694901 V-1 T = -25 °C: 15.71479939 V-1 |
Break-through voltage: | T = +20 °C: 423.8661927 V T = -25 °C: 387.2401071 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:28:11 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:58:30 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:44:45 CEST | jreher | Updated box and position via API. |
19. Dec 2019 16:36:30 CET | spankonin | Updated APD batch assignment via API. |
19. Dec 2019 15:18:59 CET | jreher | Updated APD location via API. |
19. Dec 2019 15:18:53 CET | jreher | Updated box and position via API. |
20. Oct 2017 14:31:38 CEST | markus.moritz | Entered shipped after irradiation date. |
20. Oct 2017 09:50:32 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 14:21:34 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:03 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:31:16 CEST | Tobias | Imported from Hamamatsu datasheet. |