Show Hamamatsu Avalanche Photo Diode 1401015121 - Archived data from Tue, 11. August 2020 17:24:28 CEST
This is all the information about APD 1401015121. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1401015121 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | D14 |
| Break-through voltage: | 425 V |
| Voltage for Gain 100 (T=+25°C): | 397.2 V |
| Dark current: | 7.5 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 29 |
| Position in Box: | 46 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 357 |
| Position in grid: | 15 |
| Arrival for irradiation: | 29. Sep 2017 |
| Sent for analysis after irradiation: | 16. Jan 2019 |
| Return for assembly: | none |
| Irradiation: | |
| Date: | 28. Nov 2018 |
| Dose used: | 37 Gy |
| Temperature: | 20 °C |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | 30. Nov 2018 |
| Temperature: | 80 °C |
| Duration: | 48 h |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 397.480424 V T = -25 °C: 360.8510055 V |
| Voltage for Gain 150: | T = +20 °C: 405.3936446 V T = -25 °C: 368.5993342 V |
| Voltage for Gain 200: | T = +20 °C: 409.7972688 V T = -25 °C: 372.9296143 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 4.652422934 V-1 T = -25 °C: 4.531352839 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 8.797086295 V-1 T = -25 °C: 9.352630086 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 13.94483807 V-1 T = -25 °C: 15.01564352 V-1 |
| Break-through voltage: | T = +20 °C: 424.5529574 V T = -25 °C: 387.6869234 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 05. Feb 2021 10:51:37 CET | jreher | Updated box and position via API. |
| 03. Feb 2021 18:17:43 CET | jreher | Updated box and position via API. |
| 11. Aug 2020 17:24:28 CEST | jreher | Updated APD characteristics via API. |
| 27. Nov 2019 19:34:40 CET | jreher | Updated APD location via API. |
| 25. Nov 2019 17:13:11 CET | jreher | Updated box and position via API. |
| 04. Jul 2019 11:10:11 CEST | jreher | Updated APD location via API. |
| 17. Jun 2019 11:27:42 CEST | jreher | Updated APD location via API. |
| 13. Jun 2019 11:28:14 CEST | jreher | Updated APD location via API. |
| 13. Jun 2019 11:07:32 CEST | jreher | Updated APD location via API. |
| 12. Jun 2019 16:47:36 CEST | jreher | Updated APD batch assignment via API. |
| 12. Jun 2019 16:32:31 CEST | jreher | Updated APD batch assignment via API. |
| 18. Jan 2019 14:27:35 CET | markus.moritz | |
| 03. Dec 2018 11:10:34 CET | markus.moritz | |
| 29. Sep 2017 09:56:10 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:29:03 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 23. Jun 2016 10:31:15 CEST | Tobias | Imported from Hamamatsu datasheet. |