RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1401015102 - Archived data from Wed, 03. February 2021 18:18:05 CET


This is all the information about APD 1401015102. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1401015102
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G11
Break-through voltage: 425 V
Voltage for Gain 100 (T=+25°C): 396.5 V
Dark current: 6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 32
Position in Box: 26
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 356
Position in grid: 16
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 396.8385461 V     T = -25 °C: 360.4942452 V
Voltage for Gain 150: T = +20 °C: 404.7834502 V     T = -25 °C: 368.2749667 V
Voltage for Gain 200: T = +20 °C: 409.172551 V     T = -25 °C: 372.6356394 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.478396226 V-1     T = -25 °C: 4.62070999 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.297498075 V-1     T = -25 °C: 8.640217562 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.86699372 V-1     T = -25 °C: 15.39706291 V-1
Break-through voltage: T = +20 °C: 424.9000866 V     T = -25 °C: 388.5175367 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:51:59 CET jreher Updated box and position via API.
03. Feb 2021 18:18:05 CET jreher Updated box and position via API.
11. Aug 2020 17:24:53 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:22:15 CET jreher Updated APD location via API.
25. Nov 2019 17:13:24 CET jreher Updated box and position via API.
13. Jun 2019 11:28:48 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:48 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:42 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 14:32:29 CET markus.moritz
29. Sep 2017 12:33:54 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:02 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:15 CEST Tobias Imported from Hamamatsu datasheet.