RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1401015085 - Archived data from Wed, 03. February 2021 18:18:04 CET


This is all the information about APD 1401015085. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1401015085
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B09
Break-through voltage: 429 V
Voltage for Gain 100 (T=+25°C): 400.2 V
Dark current: 7.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 32
Position in Box: 13
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 356
Position in grid: 0
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 26. Nov 2018
Return for assembly: none
   
Irradiation:  
Date: 22. Nov 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 23. Nov 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 401.0033987 V     T = -25 °C: 364.1915904 V
Voltage for Gain 150: T = +20 °C: 408.9620793 V     T = -25 °C: 372.0348867 V
Voltage for Gain 200: T = +20 °C: 413.3854195 V     T = -25 °C: 376.4080599 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.566413818 V-1     T = -25 °C: 4.460860306 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.533011869 V-1     T = -25 °C: 9.147032811 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.22863044 V-1     T = -25 °C: 14.57133918 V-1
Break-through voltage: T = +20 °C: 428.8438372 V     T = -25 °C: 392.1406109 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:51:58 CET jreher Updated box and position via API.
03. Feb 2021 18:18:04 CET jreher Updated box and position via API.
11. Aug 2020 17:24:51 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:22:14 CET jreher Updated APD location via API.
25. Nov 2019 17:13:23 CET jreher Updated box and position via API.
13. Jun 2019 11:28:47 CEST jreher Updated APD location via API.
12. Jun 2019 16:47:47 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:42 CEST jreher Updated APD batch assignment via API.
26. Nov 2018 14:35:37 CET markus.moritz
29. Sep 2017 12:33:53 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:29:01 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:31:14 CEST Tobias Imported from Hamamatsu datasheet.