Show Hamamatsu Avalanche Photo Diode 1320015076 - Archived data from Tue, 11. August 2020 17:25:30 CEST
This is all the information about APD 1320015076. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1320015076 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F09 |
Break-through voltage: | 440 V |
Voltage for Gain 100 (T=+25°C): | 412.1 V |
Dark current: | 8.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 36 |
Position in Box: | 11 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 355 |
Position in grid: | 12 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 05. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 412.2895083 V T = -25 °C: 375.3222409 V |
Voltage for Gain 150: | T = +20 °C: 420.3024563 V T = -25 °C: 383.2870894 V |
Voltage for Gain 200: | T = +20 °C: 424.7556157 V T = -25 °C: 387.7350165 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.401219519 V-1 T = -25 °C: 4.632695714 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.98265849 V-1 T = -25 °C: 8.663410972 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.02287092 V-1 T = -25 °C: 15.3207244 V-1 |
Break-through voltage: | T = +20 °C: 439.5043775 V T = -25 °C: 402.6023765 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:52:39 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:35 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:25:30 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:59 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:42 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:29:42 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:04 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:33:00 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 14:32:03 CET | markus.moritz | |
29. Sep 2017 11:18:40 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:01 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:31:14 CEST | Tobias | Imported from Hamamatsu datasheet. |