Show Hamamatsu Avalanche Photo Diode 1319014990 - Archived data from Wed, 07. October 2020 15:44:41 CEST
This is all the information about APD 1319014990. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1319014990 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | D15 |
Break-through voltage: | 446 V |
Voltage for Gain 100 (T=+25°C): | 418 V |
Dark current: | 8.7 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 284 |
Position in Box: | 45 |
EP1 batch: | 203 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 352 |
Position in grid: | 1 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 418.2951455 V T = -25 °C: 381.4958959 V |
Voltage for Gain 150: | T = +20 °C: 426.3628685 V T = -25 °C: 389.4952853 V |
Voltage for Gain 200: | T = +20 °C: 430.830959 V T = -25 °C: 393.9272478 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.377510583 V-1 T = -25 °C: 4.32858487 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.425856608 V-1 T = -25 °C: 8.392501959 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.40280798 V-1 T = -25 °C: 14.33298392 V-1 |
Break-through voltage: | T = +20 °C: 439.9738609 V T = -25 °C: 409.2739462 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:00 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:41 CEST | jreher | Updated APD location via API. |
11. Aug 2020 18:03:57 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:39:40 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:39:30 CEST | jreher | Updated box and position via API. |
10. Feb 2020 18:58:28 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:50:13 CET | jreher | Updated APD location via API. |
27. Nov 2019 20:17:49 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:02 CET | jreher | Updated box and position via API. |
22. Oct 2019 13:10:01 CEST | spankonin | Updated APD location via API. |
09. Oct 2019 11:44:01 CEST | jgrochowski | Updated APD batch assignment via API. |
29. Sep 2017 09:56:52 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:59 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:29:51 CEST | Tobias | Imported from Hamamatsu datasheet. |