Show Hamamatsu Avalanche Photo Diode 1319014974 - Archived data from Wed, 24. August 2016 14:36:40 CEST
This is all the information about APD 1319014974. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1319014974 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F07 |
Break-through voltage: | 435 V |
Voltage for Gain 100 (T=+25°C): | 406.2 V |
Dark current: | 6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 292 |
Position in Box: | 31 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 351 |
Position in grid: | 6 |
Arrival for irradiation: | 11. Aug 2016 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | 23. Aug 2016 |
Dose used: | 30 Gy |
Temperature: | 25 °C |
Position: | 2 |
Bias voltage: | 350 V (connected) |
Annealing: | |
Date: | 24. Aug 2016 |
Temperature: | 80 °C |
Duration: | 10 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:59 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:59 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:40:43 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:41:02 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:19:12 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:38 CET | jreher | Updated box and position via API. |
22. Oct 2019 14:33:21 CEST | spankonin | Updated APD location via API. |
15. Oct 2019 11:00:19 CEST | jgrochowski | Updated APD batch assignment via API. |
06. Oct 2016 09:45:00 CEST | markus.moritz | Entered return for assembly date. |
08. Sep 2016 13:36:10 CEST | markus.moritz | Entered shipped after irradiation date. |
24. Aug 2016 14:36:40 CEST | christopher.l.hahn | Entered irradiation information. |
24. Aug 2016 14:24:26 CEST | christopher.l.hahn | Entered annealing information. |
11. Aug 2016 11:48:04 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:58 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:29:50 CEST | Tobias | Imported from Hamamatsu datasheet. |