Show Hamamatsu Avalanche Photo Diode 1318014901 - Archived data from Mon, 25. November 2019 17:31:37 CET
This is all the information about APD 1318014901. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1318014901 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum Box 292 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G08 |
Break-through voltage: | 441 V |
Voltage for Gain 100 (T=+25°C): | 412.3 V |
Dark current: | 7.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 292 |
Position in Box: | 20 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 348 |
Position in grid: | 3 |
Arrival for irradiation: | 02. Nov 2016 |
Sent for analysis after irradiation: | 10. Nov 2016 |
Return for assembly: | 09. Dec 2016 |
Irradiation: | |
Date: | 04. Nov 2016 |
Dose used: | 30 Gy |
Temperature: | 20 °C |
Position: | 4 |
Bias voltage: | 350 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:58 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:57 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:40:41 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:41:01 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:19:12 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:37 CET | jreher | Updated box and position via API. |
22. Oct 2019 14:33:20 CEST | spankonin | Updated APD location via API. |
15. Oct 2019 11:00:18 CEST | jgrochowski | Updated APD batch assignment via API. |
09. Dec 2016 10:27:27 CET | markus.moritz | Entered return for assembly date. |
23. Nov 2016 10:53:56 CET | markus.moritz | Entered shipped after irradiation date. |
04. Nov 2016 16:01:58 CET | markus.moritz | Entered irradiation information. |
02. Nov 2016 14:53:20 CET | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:56 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:29:48 CEST | Tobias | Imported from Hamamatsu datasheet. |