Subdetector specification:  
Serial: 1318014849
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum Box 290
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C02
Break-through voltage: 444 V
Voltage for Gain 100 (T=+25°C): 415.6 V
Dark current: 7.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 290
Position in Box: 19
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 799
Position in grid: 14
Arrival for irradiation: 19. Sep 2016
Sent for analysis after irradiation: 30. Sep 2016
Return for assembly: 02. Nov 2016
   
Irradiation:  
Date: 27. Sep 2016
Dose used: 36 Gy
Temperature: 20 °C
Position: 2
Bias voltage: 350 V     (connected)
   
Annealing:  
Date: 28. Sep 2016
Temperature: 80 °C
Duration: 10 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:25:42 CET jreher Updated box and position via API.
11. Aug 2020 17:40:21 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:40:41 CEST jreher Updated box and position via API.
27. Nov 2019 20:18:49 CET jreher Updated APD location via API.
25. Nov 2019 17:31:28 CET jreher Updated box and position via API.
22. Oct 2019 14:31:59 CEST spankonin Updated APD location via API.
14. Oct 2019 17:31:24 CEST jgrochowski Updated APD batch assignment via API.
05. Apr 2018 14:02:48 CEST jgrochowski
02. Nov 2016 14:38:26 CET markus.moritz Entered return for assembly date.
07. Oct 2016 10:48:56 CEST christopher.l.hahn Entered irradiation information.
05. Oct 2016 15:42:51 CEST markus.moritz Entered shipped after irradiation date.
28. Sep 2016 14:01:44 CEST christopher.l.hahn Entered annealing information.
27. Sep 2016 18:02:40 CEST christopher.l.hahn Entered irradiation information.
23. Sep 2016 09:10:34 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:55 CEST Tobias Assigned to grid via information extracted from APD DB.