Show Hamamatsu Avalanche Photo Diode 1317014777 - Archived data from Fri, 05. February 2021 11:32:00 CET
This is all the information about APD 1317014777. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1317014777 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A08 |
Break-through voltage: | 443 V |
Voltage for Gain 100 (T=+25°C): | 414.7 V |
Dark current: | 7.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 341 |
Position in Box: | 22 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 343 |
Position in grid: | 2 |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
16. Apr 2021 21:59:32 CEST | jreher | Updated APD characteristics via API. |
05. Feb 2021 11:32:00 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:46 CEST | jreher | Updated APD location via API. |
17. Aug 2020 14:53:04 CEST | vwerner | Updated APD batch assignment via API. |
11. Aug 2020 17:54:03 CEST | jreher | Updated APD location via API. |
27. Oct 2017 10:23:25 CEST | Tobias | Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated. |
29. Sep 2017 09:52:57 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:53 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:29:46 CEST | Tobias | Imported from Hamamatsu datasheet. |