Subdetector specification:  
Serial: 1315014677
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C13
Break-through voltage: 447 V
Voltage for Gain 100 (T=+25°C): 418.4 V
Dark current: 10.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 35
Position in Box: 26
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 338
Position in grid: 15
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 03. Jan 2019
Return for assembly: none
   
Irradiation:  
Date: 05. Dec 2018
Dose used: 37 Gy
Temperature: 20 °C
Position: none
Bias voltage: none     
   
Annealing:  
Date: 10. Dec 2018
Temperature: 80 °C
Duration: 48 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 419.0475332 V     T = -25 °C: 382.2826727 V
Voltage for Gain 150: T = +20 °C: 427.0261171 V     T = -25 °C: 390.2294492 V
Voltage for Gain 200: T = +20 °C: 431.4728633 V     T = -25 °C: 394.5993126 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.466716562 V-1     T = -25 °C: 4.439611077 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.645483814 V-1     T = -25 °C: 9.312529568 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.65845317 V-1     T = -25 °C: 15.00886771 V-1
Break-through voltage: T = +20 °C: 439.8581073 V     T = -25 °C: 410.4890204 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 10:52:28 CET jreher Updated box and position via API.
03. Feb 2021 18:18:29 CET jreher Updated box and position via API.
07. Oct 2020 15:45:57 CEST jreher Updated APD location via API.
11. Aug 2020 17:25:23 CEST jreher Updated APD characteristics via API.
28. Nov 2019 12:22:49 CET jreher Updated APD location via API.
25. Nov 2019 17:13:38 CET jreher Updated box and position via API.
13. Jun 2019 11:29:29 CEST jreher Updated APD location via API.
12. Jun 2019 16:48:01 CEST jreher Updated APD batch assignment via API.
12. Jun 2019 16:32:57 CEST jreher Updated APD batch assignment via API.
03. Jan 2019 13:22:00 CET markus.moritz
29. Sep 2017 10:21:51 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:50 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:29:43 CEST Tobias Imported from Hamamatsu datasheet.