Show Hamamatsu Avalanche Photo Diode 1315014675 - Archived data from Wed, 03. February 2021 18:18:28 CET
This is all the information about APD 1315014675. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1315014675 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F15 |
Break-through voltage: | 444 V |
Voltage for Gain 100 (T=+25°C): | 416.3 V |
Dark current: | 10.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 35 |
Position in Box: | 24 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 338 |
Position in grid: | 13 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 05. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 416.7148483 V T = -25 °C: 379.5863535 V |
Voltage for Gain 150: | T = +20 °C: 424.7825929 V T = -25 °C: 387.5770066 V |
Voltage for Gain 200: | T = +20 °C: 429.2715109 V T = -25 °C: 392.0284434 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.452712109 V-1 T = -25 °C: 4.405634022 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.377484597 V-1 T = -25 °C: 9.128719254 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.81146744 V-1 T = -25 °C: 15.02465047 V-1 |
Break-through voltage: | T = +20 °C: 439.7491981 V T = -25 °C: 406.4769266 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:52:28 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:28 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:56 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:25:23 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:49 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:38 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:29:29 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:01 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:56 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 13:21:32 CET | markus.moritz | |
03. Jan 2019 13:21:17 CET | markus.moritz | |
29. Sep 2017 10:21:51 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:50 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:29:43 CEST | Tobias | Imported from Hamamatsu datasheet. |