Show Hamamatsu Avalanche Photo Diode 1315014669 - Archived data from Tue, 11. August 2020 17:25:22 CEST
This is all the information about APD 1315014669. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1315014669 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F12 |
Break-through voltage: | 440 V |
Voltage for Gain 100 (T=+25°C): | 415.4 V |
Dark current: | 7.8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 35 |
Position in Box: | 21 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 338 |
Position in grid: | 8 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 05. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 416.0581328 V T = -25 °C: 379.2195269 V |
Voltage for Gain 150: | T = +20 °C: 423.9951427 V T = -25 °C: 387.0561581 V |
Voltage for Gain 200: | T = +20 °C: 428.3941419 V T = -25 °C: 391.453976 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.389746606 V-1 T = -25 °C: 4.580031436 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.288677408 V-1 T = -25 °C: 9.12690844 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.1661318 V-1 T = -25 °C: 14.79383386 V-1 |
Break-through voltage: | T = +20 °C: 439.8721921 V T = -25 °C: 407.1423158 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:52:27 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:28 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:56 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:25:22 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:49 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:38 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:29:29 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:01 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:56 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 13:19:55 CET | markus.moritz | |
29. Sep 2017 10:21:51 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:49 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:29:43 CEST | Tobias | Imported from Hamamatsu datasheet. |