Show Hamamatsu Avalanche Photo Diode 1315014649 - Archived data from Tue, 11. August 2020 17:40:37 CEST
This is all the information about APD 1315014649. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1315014649 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A08 |
Break-through voltage: | 443 V |
Voltage for Gain 100 (T=+25°C): | 414.4 V |
Dark current: | 9.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 291 |
Position in Box: | 50 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 337 |
Position in grid: | 13 |
Arrival for irradiation: | 27. Oct 2016 |
Sent for analysis after irradiation: | 02. Nov 2016 |
Return for assembly: | 09. Dec 2016 |
Irradiation: | |
Date: | 31. Oct 2016 |
Dose used: | 30 Gy |
Temperature: | 20 °C |
Position: | 2 |
Bias voltage: | 350 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 414.7476777 V T = -25 °C: 378.1568117 V |
Voltage for Gain 150: | T = +20 °C: 422.6718027 V T = -25 °C: 385.9878201 V |
Voltage for Gain 200: | T = +20 °C: 427.0701199 V T = -25 °C: 390.3460199 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.590924728 V-1 T = -25 °C: 4.536193967 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.043681921 V-1 T = -25 °C: 8.906055957 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.12358926 V-1 T = -25 °C: 15.6191443 V-1 |
Break-through voltage: | T = +20 °C: 436.6027082 V T = -25 °C: 405.9963183 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:54 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:55 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:40:37 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:40:54 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:19:03 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:35 CET | jreher | Updated box and position via API. |
22. Oct 2019 14:32:48 CEST | spankonin | Updated APD location via API. |
15. Oct 2019 11:00:39 CEST | jgrochowski | Updated APD batch assignment via API. |
09. Dec 2016 10:28:48 CET | markus.moritz | Entered return for assembly date. |
02. Nov 2016 14:31:08 CET | markus.moritz | Entered shipped after irradiation date. |
02. Nov 2016 14:16:10 CET | markus.moritz | Entered irradiation information. |
27. Oct 2016 12:05:42 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:29:45 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:29:43 CEST | Tobias | Imported from Hamamatsu datasheet. |