Show Hamamatsu Avalanche Photo Diode 1315014628 - Archived data from Tue, 11. August 2020 17:39:59 CEST
This is all the information about APD 1315014628. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1315014628 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F06 |
Break-through voltage: | 435 V |
Voltage for Gain 100 (T=+25°C): | 406.5 V |
Dark current: | 7.3 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 288 |
Position in Box: | 8 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 336 |
Position in grid: | 13 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | 22. Feb 2018 |
Dose used: | 30 Gy |
Temperature: | 25 °C |
Position: | 4 |
Bias voltage: | 0 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 406.5065375 V T = -25 °C: 370.1207956 V |
Voltage for Gain 150: | T = +20 °C: 414.4742408 V T = -25 °C: 377.9322347 V |
Voltage for Gain 200: | T = +20 °C: 418.8845735 V T = -25 °C: 382.2660747 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.368968262 V-1 T = -25 °C: 4.600512766 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.500053682 V-1 T = -25 °C: 9.128653453 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.68087767 V-1 T = -25 °C: 14.28188169 V-1 |
Break-through voltage: | T = +20 °C: 429.564568 V T = -25 °C: 398.1463281 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:25 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:42 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:39:59 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:40:19 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:18:27 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:17 CET | jreher | Updated box and position via API. |
22. Oct 2019 14:30:37 CEST | spankonin | Updated APD location via API. |
09. Oct 2019 11:26:59 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Apr 2018 12:29:13 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 12:05:25 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:49 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:29:42 CEST | Tobias | Imported from Hamamatsu datasheet. |