Subdetector specification: | |
---|---|
Serial: | 1315014627 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | E05 |
Break-through voltage: | 435 V |
Voltage for Gain 100 (T=+25°C): | 406.9 V |
Dark current: | 8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 288 |
Position in Box: | 7 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 336 |
Position in grid: | 12 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | 22. Feb 2018 |
Dose used: | 30 Gy |
Temperature: | 25 °C |
Position: | 4 |
Bias voltage: | 0 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 407.3599546 V T = -25 °C: 370.6312062 V |
Voltage for Gain 150: | T = +20 °C: 415.2616089 V T = -25 °C: 378.4424316 V |
Voltage for Gain 200: | T = +20 °C: 419.6378801 V T = -25 °C: 382.7716431 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.466448991 V-1 T = -25 °C: 4.431840216 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.724947891 V-1 T = -25 °C: 8.669383438 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.19362207 V-1 T = -25 °C: 15.12458775 V-1 |
Break-through voltage: | T = +20 °C: 431.3370946 V T = -25 °C: 398.51859 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:25 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:42 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:39:58 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:40:19 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:18:27 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:17 CET | jreher | Updated box and position via API. |
22. Oct 2019 14:30:37 CEST | spankonin | Updated APD location via API. |
09. Oct 2019 11:26:59 CEST | jgrochowski | Updated APD batch assignment via API. |
05. Apr 2018 12:29:13 CEST | markus.moritz | Entered irradiation information. |
29. Sep 2017 12:05:25 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:49 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:29:42 CEST | Tobias | Imported from Hamamatsu datasheet. |