RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1315014625 - Archived data from Tue, 11. August 2020 17:39:58 CEST


This is all the information about APD 1315014625. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1315014625
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C10
Break-through voltage: 441 V
Voltage for Gain 100 (T=+25°C): 412.4 V
Dark current: 10.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 288
Position in Box: 5
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 336
Position in grid: 10
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: 22. Feb 2018
Dose used: 30 Gy
Temperature: 25 °C
Position: 4
Bias voltage: 0 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 413.130952 V     T = -25 °C: 376.4634813 V
Voltage for Gain 150: T = +20 °C: 421.0372842 V     T = -25 °C: 384.2795802 V
Voltage for Gain 200: T = +20 °C: 425.4268832 V     T = -25 °C: 388.610783 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.531600377 V-1     T = -25 °C: 4.499028871 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.995259671 V-1     T = -25 °C: 8.885546967 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.040733 V-1     T = -25 °C: 15.68616411 V-1
Break-through voltage: T = +20 °C: 439.8701206 V     T = -25 °C: 403.5721454 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:25:25 CET jreher Updated box and position via API.
07. Oct 2020 15:44:42 CEST jreher Updated APD location via API.
11. Aug 2020 17:39:58 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:40:19 CEST jreher Updated box and position via API.
27. Nov 2019 20:18:26 CET jreher Updated APD location via API.
25. Nov 2019 17:31:17 CET jreher Updated box and position via API.
22. Oct 2019 14:30:37 CEST spankonin Updated APD location via API.
09. Oct 2019 11:26:58 CEST jgrochowski Updated APD batch assignment via API.
05. Apr 2018 12:29:13 CEST markus.moritz Entered irradiation information.
29. Sep 2017 12:05:25 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:49 CEST Tobias Assigned to grid via information extracted from APD DB.
23. Jun 2016 10:29:42 CEST Tobias Imported from Hamamatsu datasheet.