Show Hamamatsu Avalanche Photo Diode 0915010086 - Archived data from Tue, 02. August 2016 14:56:29 CEST
This is all the information about APD 0915010086. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 0915010086 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F10 |
Break-through voltage: | 407 V |
Voltage for Gain 100 (T=+25°C): | 378.5 V |
Dark current: | 5.5 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 44 |
Position in Box: | 49 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 223 |
Position in grid: | 8 |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 05. Jul 2016 |
Temperature: | 80 °C |
Duration: | 8 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
22. Feb 2021 11:10:51 CET | jreher | Updated box and position via API. |
05. Feb 2021 10:53:54 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:19:41 CET | jreher | Updated box and position via API. |
08. Dec 2020 17:17:22 CET | jreher | Assigned to capsule by script |
06. Oct 2020 16:52:04 CEST | jreher | Updated box and position via API. |
11. Aug 2020 17:26:56 CEST | jreher | Updated APD characteristics via API. |
04. Aug 2020 15:48:21 CEST | jreher | Updated box and position via API. |
27. Nov 2019 19:36:51 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:14:27 CET | jreher | Updated box and position via API. |
04. Jul 2019 11:11:38 CEST | jreher | Updated APD location via API. |
13. Jun 2019 10:01:31 CEST | jreher | Updated APD batch assignment via API. |
12. Sep 2016 09:51:55 CEST | markus.moritz | Entered return for assembly date. |
03. Aug 2016 16:41:04 CEST | markus.moritz | Entered irradiation information. |
03. Aug 2016 16:15:32 CEST | markus.moritz | Entered shipped after irradiation date. |
03. Aug 2016 16:15:21 CEST | markus.moritz | Entered arrival for irradiation date. |
02. Aug 2016 14:56:29 CEST | christopher.l.hahn | Entered annealing information. |
01. Aug 2016 17:27:33 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
23. Jun 2016 10:26:44 CEST | Tobias | Imported from Hamamatsu datasheet. |