Show Hamamatsu Avalanche Photo Diode 1314014590 - Archived data from Wed, 10. November 2021 14:35:21 CET


This is all the information about APD 1314014590. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1314014590
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F06
Break-through voltage: 443 V
Voltage for Gain 100 (T=+25°C): 414.7 V
Dark current: 8.3 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 326
Position in Box: 37
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 334
Position in grid: 16
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 1.036264788 V     T = -25 °C: 377.525505 V
Voltage for Gain 150: T = +20 °C: 1.621620553 V     T = -25 °C: 385.4724471 V
Voltage for Gain 200: T = +20 °C: 438.02249 V     T = -25 °C: 389.8693672 V
Gain/Voltage slope at M = 100: T = +20 °C: 54.38204431 V-1     T = -25 °C: 4.394227448 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 54.38204431 V-1     T = -25 °C: 8.506309702 V-1
Gain/Voltage slope at M = 200: T = +20 °C: -719.9108699 V-1     T = -25 °C: 14.6287166 V-1
Break-through voltage: T = +20 °C: 439.984331 V     T = -25 °C: 405.5570429 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:24 CET jreher Updated APD characteristics via API.
10. Nov 2021 14:35:21 CET oafedulidis Updated APD location via API.
10. Nov 2021 14:35:07 CET oafedulidis Updated APD batch assignment via API.
05. Feb 2021 11:30:12 CET jreher Updated box and position via API.
07. Oct 2020 15:45:19 CEST jreher Updated APD location via API.
11. Aug 2020 18:09:25 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:46:07 CEST jreher Updated APD location via API.
21. Jul 2020 14:45:57 CEST jreher Updated box and position via API.
09. Jul 2020 15:02:40 CEST jreher Updated APD batch assignment via API.
27. Oct 2017 10:23:25 CEST Tobias Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated.
29. Sep 2017 09:53:31 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:48 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:42:38 CEST Tobias Imported from Hamamatsu datasheet.