Show Hamamatsu Avalanche Photo Diode 1314014577 - Archived data from Wed, 10. November 2021 14:35:20 CET
This is all the information about APD 1314014577. If it is wrong, edit the data.
| Subdetector specification: | |
|---|---|
| Serial: | 1314014577 |
| Type: | Hamamatsu Avalanche Photo Diode |
| Detector: | unassigned |
| Unit: | unassigned |
| Preamp: | 0 |
| Current location: | Bochum |
| Installation information: | |
| Label: | none |
| Manufacturer information: | |
| Wafer position: | H08 |
| Break-through voltage: | 444 V |
| Voltage for Gain 100 (T=+25°C): | 415.7 V |
| Dark current: | 5 nA |
| Screening Logistics: | |
| Available: | Yes |
| Storage Box: | 326 |
| Position in Box: | 25 |
| EP1 batch: | none |
| EP1 batch after irradiation: | none |
| Shipment: | |
| Grid number: | 334 |
| Position in grid: | 4 |
| Arrival for irradiation: | none |
| Sent for analysis after irradiation: | none |
| Return for assembly: | none |
| Irradiation: | |
| Date: | none |
| Dose used: | none |
| Temperature: | none |
| Position: | none |
| Bias voltage: | none |
| Annealing: | |
| Date: | none |
| Temperature: | none |
| Duration: | none |
| Measurement results: | |
| Voltage for Gain 100: | T = +20 °C: 400.9557029 V T = -25 °C: 379.432695 V |
| Voltage for Gain 150: | T = +20 °C: 412.3345046 V T = -25 °C: 387.3692194 V |
| Voltage for Gain 200: | T = +20 °C: 418.9126522 V T = -25 °C: 391.7769331 V |
| Gain/Voltage slope at M = 100: | T = +20 °C: 3.295976771 V-1 T = -25 °C: 4.437856702 V-1 |
| Gain/Voltage slope at M = 150: | T = +20 °C: 6.061778097 V-1 T = -25 °C: 8.644465416 V-1 |
| Gain/Voltage slope at M = 200: | T = +20 °C: 9.852925792 V-1 T = -25 °C: 15.10248899 V-1 |
| Break-through voltage: | T = +20 °C: 439.992284 V T = -25 °C: 406.4210466 V |
| Notes: |
Version history
| Time | Author | Change comment |
|---|---|---|
| 07. Feb 2022 16:17:21 CET | jreher | Updated APD characteristics via API. |
| 10. Nov 2021 14:35:20 CET | oafedulidis | Updated APD location via API. |
| 10. Nov 2021 14:35:05 CET | oafedulidis | Updated APD batch assignment via API. |
| 05. Feb 2021 11:30:11 CET | jreher | Updated box and position via API. |
| 07. Oct 2020 15:45:17 CEST | jreher | Updated APD location via API. |
| 11. Aug 2020 18:09:22 CEST | jreher | Updated APD characteristics via API. |
| 21. Jul 2020 14:46:06 CEST | jreher | Updated APD location via API. |
| 21. Jul 2020 14:45:56 CEST | jreher | Updated box and position via API. |
| 09. Jul 2020 15:02:39 CEST | jreher | Updated APD batch assignment via API. |
| 27. Oct 2017 10:23:25 CEST | Tobias | Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated. |
| 29. Sep 2017 09:53:30 CEST | markus.moritz | Entered arrival for irradiation date. |
| 01. Aug 2016 17:28:47 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
| 22. Jun 2016 15:42:37 CEST | Tobias | Imported from Hamamatsu datasheet. |