Show Hamamatsu Avalanche Photo Diode 1314014570 - Archived data from Wed, 07. October 2020 15:45:17 CEST
This is all the information about APD 1314014570. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1314014570 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F13 |
Break-through voltage: | 449 V |
Voltage for Gain 100 (T=+25°C): | 420.9 V |
Dark current: | 9.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 326 |
Position in Box: | 20 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 333 |
Position in grid: | 19 |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 421.0547999 V T = -25 °C: 364.8272077 V |
Voltage for Gain 150: | T = +20 °C: 428.9479286 V T = -25 °C: 366.9564126 V |
Voltage for Gain 200: | T = +20 °C: 433.3284218 V T = -25 °C: 374.5865739 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.587002434 V-1 T = -25 °C: 216.6111312 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.970150443 V-1 T = -25 °C: 265.3393791 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 13.96119738 V-1 T = -25 °C: 379.8259948 V-1 |
Break-through voltage: | T = +20 °C: 439.2753835 V T = -25 °C: 412.7406898 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
07. Feb 2022 16:17:21 CET | jreher | Updated APD characteristics via API. |
10. Nov 2021 14:35:19 CET | oafedulidis | Updated APD location via API. |
10. Nov 2021 14:35:04 CET | oafedulidis | Updated APD batch assignment via API. |
05. Feb 2021 11:30:10 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:17 CEST | jreher | Updated APD location via API. |
11. Aug 2020 18:09:21 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:46:05 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:45:56 CEST | jreher | Updated box and position via API. |
09. Jul 2020 15:02:16 CEST | jreher | Updated APD batch assignment via API. |
27. Oct 2017 10:23:25 CEST | Tobias | Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated. |
29. Sep 2017 12:28:30 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:47 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:42:37 CEST | Tobias | Imported from Hamamatsu datasheet. |