RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1314014565 - Archived data from Fri, 05. February 2021 11:30:09 CET


This is all the information about APD 1314014565. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1314014565
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E13
Break-through voltage: 450 V
Voltage for Gain 100 (T=+25°C): 421.5 V
Dark current: 8.1 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 326
Position in Box: 15
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 333
Position in grid: 14
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 421.8392264 V     T = -25 °C: 364.4938156 V
Voltage for Gain 150: T = +20 °C: 429.7533202 V     T = -25 °C: 364.8100856 V
Voltage for Gain 200: T = +20 °C: 439.113152 V     T = -25 °C: 373.5018423 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.628493951 V-1     T = -25 °C: 158.092749 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.166978896 V-1     T = -25 °C: 158.092749 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 6.975028172 V-1     T = -25 °C: 170.5234626 V-1
Break-through voltage: T = +20 °C: 439.292419 V     T = -25 °C: 413.499997 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:20 CET jreher Updated APD characteristics via API.
10. Nov 2021 14:35:19 CET oafedulidis Updated APD location via API.
10. Nov 2021 14:35:04 CET oafedulidis Updated APD batch assignment via API.
05. Feb 2021 11:30:09 CET jreher Updated box and position via API.
07. Oct 2020 15:45:17 CEST jreher Updated APD location via API.
11. Aug 2020 18:09:20 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:46:05 CEST jreher Updated APD location via API.
21. Jul 2020 14:45:55 CEST jreher Updated box and position via API.
09. Jul 2020 15:02:15 CEST jreher Updated APD batch assignment via API.
27. Oct 2017 10:23:25 CEST Tobias Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated.
29. Sep 2017 12:28:30 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:47 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:42:37 CEST Tobias Imported from Hamamatsu datasheet.