Subdetector specification:  
Serial: 1314014562
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F07
Break-through voltage: 443 V
Voltage for Gain 100 (T=+25°C): 414.6 V
Dark current: 8.6 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 326
Position in Box: 12
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 333
Position in grid: 11
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 414.3725002 V     T = -25 °C: 364.4937819 V
Voltage for Gain 150: T = +20 °C: 422.3676949 V     T = -25 °C: 368.645391 V
Voltage for Gain 200: T = +20 °C: 426.8044638 V     T = -25 °C: 372.7286067 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.416728377 V-1     T = -25 °C: 109.5224461 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.510275547 V-1     T = -25 °C: 128.5042705 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.577012 V-1     T = -25 °C: 106.2019227 V-1
Break-through voltage: T = +20 °C: 437.5536568 V     T = -25 °C: 405.3879469 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:19 CET jreher Updated APD characteristics via API.
10. Nov 2021 14:35:18 CET oafedulidis Updated APD location via API.
10. Nov 2021 14:35:03 CET oafedulidis Updated APD batch assignment via API.
05. Feb 2021 11:30:09 CET jreher Updated box and position via API.
07. Oct 2020 15:45:16 CEST jreher Updated APD location via API.
11. Aug 2020 18:09:20 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:46:05 CEST jreher Updated APD location via API.
21. Jul 2020 14:45:55 CEST jreher Updated box and position via API.
09. Jul 2020 15:02:15 CEST jreher Updated APD batch assignment via API.
27. Oct 2017 10:23:25 CEST Tobias Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated.
29. Sep 2017 12:28:30 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:47 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:42:37 CEST Tobias Imported from Hamamatsu datasheet.