Show Hamamatsu Avalanche Photo Diode 1314014552 - Archived data from Wed, 07. October 2020 15:45:15 CEST
This is all the information about APD 1314014552. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1314014552 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G04 |
Break-through voltage: | 443 V |
Voltage for Gain 100 (T=+25°C): | 414.8 V |
Dark current: | 8 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 326 |
Position in Box: | 4 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 333 |
Position in grid: | 3 |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 415.7249142 V T = -25 °C: 367.4548343 V |
Voltage for Gain 150: | T = +20 °C: 423.6536056 V T = -25 °C: 381.0177249 V |
Voltage for Gain 200: | T = +20 °C: 428.0535074 V T = -25 °C: 381.6296782 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.636199649 V-1 T = -25 °C: 96.95574532 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.17209832 V-1 T = -25 °C: 81.70559108 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.29286348 V-1 T = -25 °C: 81.70559108 V-1 |
Break-through voltage: | T = +20 °C: 438.5762075 V T = -25 °C: 406.8899186 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
07. Feb 2022 16:17:18 CET | jreher | Updated APD characteristics via API. |
10. Nov 2021 14:34:48 CET | oafedulidis | Updated APD location via API. |
10. Nov 2021 14:34:33 CET | oafedulidis | Updated APD batch assignment via API. |
05. Feb 2021 11:30:08 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:15 CEST | jreher | Updated APD location via API. |
11. Aug 2020 18:09:18 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:46:04 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:45:54 CEST | jreher | Updated box and position via API. |
09. Jul 2020 15:02:14 CEST | jreher | Updated APD batch assignment via API. |
27. Oct 2017 10:23:25 CEST | Tobias | Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated. |
29. Sep 2017 12:28:30 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:47 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:42:37 CEST | Tobias | Imported from Hamamatsu datasheet. |