Show Hamamatsu Avalanche Photo Diode 1314014546 - Archived data from Tue, 11. August 2020 18:03:52 CEST
This is all the information about APD 1314014546. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1314014546 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | B04 |
Break-through voltage: | 447 V |
Voltage for Gain 100 (T=+25°C): | 418.6 V |
Dark current: | 9.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 284 |
Position in Box: | 18 |
EP1 batch: | 202 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 332 |
Position in grid: | 17 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 418.6398379 V T = -25 °C: 382.1074055 V |
Voltage for Gain 150: | T = +20 °C: 426.6131195 V T = -25 °C: 389.9413415 V |
Voltage for Gain 200: | T = +20 °C: 431.0125088 V T = -25 °C: 394.2923451 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.324834339 V-1 T = -25 °C: 4.569479705 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.272966803 V-1 T = -25 °C: 9.082462095 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.41862792 V-1 T = -25 °C: 14.18367877 V-1 |
Break-through voltage: | T = +20 °C: 439.977932 V T = -25 °C: 410.0720246 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:24:57 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:39 CEST | jreher | Updated APD location via API. |
11. Aug 2020 18:03:52 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:39:38 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:39:28 CEST | jreher | Updated box and position via API. |
10. Feb 2020 18:58:26 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:50:10 CET | jreher | Updated APD location via API. |
27. Nov 2019 20:17:47 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:00 CET | jreher | Updated box and position via API. |
22. Oct 2019 13:09:59 CEST | spankonin | Updated APD location via API. |
09. Oct 2019 11:41:27 CEST | jgrochowski | Updated APD batch assignment via API. |
29. Sep 2017 11:16:01 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:46 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:42:37 CEST | Tobias | Imported from Hamamatsu datasheet. |