Subdetector specification:  
Serial: 1314014539
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C13
Break-through voltage: 451 V
Voltage for Gain 100 (T=+25°C): 422.3 V
Dark current: 8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 284
Position in Box: 12
EP1 batch: 201
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 332
Position in grid: 11
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 423.0475358 V     T = -25 °C: 386.0627222 V
Voltage for Gain 150: T = +20 °C: 430.9269152 V     T = -25 °C: 393.9991317 V
Voltage for Gain 200: T = +20 °C: 435.3186657 V     T = -25 °C: 398.4302134 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.58262371 V-1     T = -25 °C: 4.546425869 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.000830554 V-1     T = -25 °C: 8.952619087 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.95491579 V-1     T = -25 °C: 13.58735456 V-1
Break-through voltage: T = +20 °C: 440.0196726 V     T = -25 °C: 414.3075805 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:57 CET jreher Updated box and position via API.
07. Oct 2020 15:44:38 CEST jreher Updated APD location via API.
11. Aug 2020 18:03:50 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:37 CEST jreher Updated APD location via API.
21. Jul 2020 14:39:28 CEST jreher Updated box and position via API.
10. Feb 2020 18:58:54 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:10 CET jreher Updated APD location via API.
27. Nov 2019 20:17:47 CET jreher Updated APD location via API.
25. Nov 2019 17:30:59 CET jreher Updated box and position via API.
22. Oct 2019 13:09:59 CEST spankonin Updated APD location via API.
09. Oct 2019 11:37:45 CEST jgrochowski Updated APD batch assignment via API.
29. Sep 2017 11:16:01 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:46 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:42:37 CEST Tobias Imported from Hamamatsu datasheet.