Show Hamamatsu Avalanche Photo Diode 1313014537 - Archived data from Tue, 11. August 2020 18:03:49 CEST
This is all the information about APD 1313014537. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1313014537 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G07 |
Break-through voltage: | 438 V |
Voltage for Gain 100 (T=+25°C): | 409.9 V |
Dark current: | 7.6 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 284 |
Position in Box: | 10 |
EP1 batch: | 201 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 332 |
Position in grid: | 9 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 410.9788592 V T = -25 °C: 373.2247279 V |
Voltage for Gain 150: | T = +20 °C: 418.7747807 V T = -25 °C: 381.2412309 V |
Voltage for Gain 200: | T = +20 °C: 423.574948 V T = -25 °C: 385.710409 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.650785073 V-1 T = -25 °C: 4.404396911 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.203761391 V-1 T = -25 °C: 8.56914246 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.5925901 V-1 T = -25 °C: 14.74367034 V-1 |
Break-through voltage: | T = +20 °C: 426.7053482 V T = -25 °C: 401.984084 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:24:56 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:38 CEST | jreher | Updated APD location via API. |
11. Aug 2020 18:03:49 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:39:37 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:39:27 CEST | jreher | Updated box and position via API. |
10. Feb 2020 18:58:54 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:50:10 CET | jreher | Updated APD location via API. |
27. Nov 2019 20:17:46 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:30:59 CET | jreher | Updated box and position via API. |
22. Oct 2019 13:09:58 CEST | spankonin | Updated APD location via API. |
09. Oct 2019 11:37:45 CEST | jgrochowski | Updated APD batch assignment via API. |
29. Sep 2017 11:16:01 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:46 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:42:37 CEST | Tobias | Imported from Hamamatsu datasheet. |