RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1313014525 - Archived data from Tue, 11. August 2020 18:03:48 CEST


This is all the information about APD 1313014525. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1313014525
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: E06
Break-through voltage: 438 V
Voltage for Gain 100 (T=+25°C): 409.6 V
Dark current: 8 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 284
Position in Box: 1
EP1 batch: 201
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 332
Position in grid: 0
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 409.6514439 V     T = -25 °C: 372.6045131 V
Voltage for Gain 150: T = +20 °C: 417.7304413 V     T = -25 °C: 380.5946873 V
Voltage for Gain 200: T = +20 °C: 422.2117522 V     T = -25 °C: 385.0496955 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.24793847 V-1     T = -25 °C: 4.359749043 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.948331523 V-1     T = -25 °C: 9.110726374 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.73818525 V-1     T = -25 °C: 14.13972998 V-1
Break-through voltage: T = +20 °C: 438.1026369 V     T = -25 °C: 401.2856975 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:55 CET jreher Updated box and position via API.
07. Oct 2020 15:44:37 CEST jreher Updated APD location via API.
11. Aug 2020 18:03:48 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:37 CEST jreher Updated APD location via API.
21. Jul 2020 14:39:27 CEST jreher Updated box and position via API.
10. Feb 2020 18:58:53 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:09 CET jreher Updated APD location via API.
27. Nov 2019 20:17:46 CET jreher Updated APD location via API.
25. Nov 2019 17:30:58 CET jreher Updated box and position via API.
22. Oct 2019 13:09:58 CEST spankonin Updated APD location via API.
09. Oct 2019 11:37:44 CEST jgrochowski Updated APD batch assignment via API.
29. Sep 2017 11:16:01 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:46 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:42:36 CEST Tobias Imported from Hamamatsu datasheet.