Show Hamamatsu Avalanche Photo Diode 1313014475 - Archived data from Wed, 10. November 2021 14:35:35 CET
This is all the information about APD 1313014475. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1313014475 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F08 |
Break-through voltage: | 437 V |
Voltage for Gain 100 (T=+25°C): | 408.8 V |
Dark current: | 8.4 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 326 |
Position in Box: | 46 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 330 |
Position in grid: | 5 |
Arrival for irradiation: | none |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 399.3295412 V T = -25 °C: 372.1123697 V |
Voltage for Gain 150: | T = +20 °C: 409.481149 V T = -25 °C: 379.9971556 V |
Voltage for Gain 200: | T = +20 °C: 415.2492224 V T = -25 °C: 384.3899498 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 3.55907634 V-1 T = -25 °C: 4.528686738 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 6.691988429 V-1 T = -25 °C: 8.917238389 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 10.88476963 V-1 T = -25 °C: 13.81013998 V-1 |
Break-through voltage: | T = +20 °C: 436.8222801 V T = -25 °C: 400.0034962 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
07. Feb 2022 16:17:25 CET | jreher | Updated APD characteristics via API. |
10. Nov 2021 14:35:50 CET | oafedulidis | Updated APD location via API. |
10. Nov 2021 14:35:35 CET | oafedulidis | Updated APD batch assignment via API. |
05. Feb 2021 11:30:13 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:20 CEST | jreher | Updated APD location via API. |
11. Aug 2020 18:09:26 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:46:07 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:45:58 CEST | jreher | Updated box and position via API. |
09. Jul 2020 15:02:40 CEST | jreher | Updated APD batch assignment via API. |
01. Aug 2016 17:28:44 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:42:35 CEST | Tobias | Imported from Hamamatsu datasheet. |