Show Hamamatsu Avalanche Photo Diode 1310014276 - Archived data from Tue, 08. March 2022 14:29:17 CET


This is all the information about APD 1310014276. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1310014276
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F05
Break-through voltage: 434 V
Voltage for Gain 100 (T=+25°C): 405.8 V
Dark current: 9.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 323
Position in Box: 10
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 321
Position in grid: 13
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 406.3952727 V     T = -25 °C: 369.845484 V
Voltage for Gain 150: T = +20 °C: 414.3308811 V     T = -25 °C: 377.7041436 V
Voltage for Gain 200: T = +20 °C: 418.7314567 V     T = -25 °C: 382.069259 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.422516149 V-1     T = -25 °C: 4.659022061 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.62075867 V-1     T = -25 °C: 9.28689735 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.9951215 V-1     T = -25 °C: 14.42987652 V-1
Break-through voltage: T = +20 °C: 429.9783361 V     T = -25 °C: 397.8205533 V
   
Notes:


Version history

Time Author Change comment
28. Jul 2022 13:18:05 CEST oafedulidis Updated box and position via API.
28. Jul 2022 13:15:20 CEST oafedulidis Updated APD location via API.
08. Mar 2022 14:29:17 CET oafedulidis Updated APD characteristics via API.
08. Mar 2022 13:53:30 CET oafedulidis Updated APD batch assignment via API.
28. Feb 2022 15:57:49 CET oafedulidis Updated APD batch assignment via API.
22. Feb 2022 10:42:37 CET oafedulidis Updated APD location via API.
22. Feb 2022 10:42:21 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:58:43 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:29:45 CET jreher Updated box and position via API.
07. Oct 2020 15:45:11 CEST jreher Updated APD location via API.
11. Aug 2020 17:53:13 CEST jreher Updated APD location via API.
21. Jul 2020 16:26:37 CEST jreher Updated APD batch assignment via API.
03. Nov 2017 11:27:20 CET Tobias Resetted arrival for irradiation date because APD was returned to GSI un-irradiated.
29. Sep 2017 11:17:01 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:38 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:42:31 CEST Tobias Imported from Hamamatsu datasheet.