Show Hamamatsu Avalanche Photo Diode 1307014055 - Archived data from Tue, 11. August 2020 17:40:48 CEST
This is all the information about APD 1307014055. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1307014055 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F05 |
Break-through voltage: | 438.4 V |
Voltage for Gain 100 (T=+25°C): | 410.1 V |
Dark current: | 6.51 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 293 |
Position in Box: | 4 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 311 |
Position in grid: | 11 |
Arrival for irradiation: | 27. Oct 2016 |
Sent for analysis after irradiation: | 02. Nov 2016 |
Return for assembly: | 29. Nov 2016 |
Irradiation: | |
Date: | 31. Oct 2016 |
Dose used: | 30 Gy |
Temperature: | 20 °C |
Position: | 3 |
Bias voltage: | 350 V (not connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 410.7646132 V T = -25 °C: 373.9081268 V |
Voltage for Gain 150: | T = +20 °C: 418.7186277 V T = -25 °C: 381.9211876 V |
Voltage for Gain 200: | T = +20 °C: 423.1274692 V T = -25 °C: 386.0743993 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.604689477 V-1 T = -25 °C: 4.498911941 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.093187283 V-1 T = -25 °C: 9.07383784 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.15138093 V-1 T = -25 °C: 13.2705775 V-1 |
Break-through voltage: | T = +20 °C: 438.917219 V T = -25 °C: 402.217006 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:26:04 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:40:48 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:41:10 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:19:21 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:40 CET | jreher | Updated box and position via API. |
11. Nov 2019 15:43:03 CET | spankonin | Updated APD location via API. |
15. Oct 2019 10:59:39 CEST | jgrochowski | Updated APD batch assignment via API. |
29. Nov 2016 11:51:42 CET | markus.moritz | Entered return for assembly date. |
02. Nov 2016 14:30:44 CET | markus.moritz | Entered shipped after irradiation date. |
02. Nov 2016 14:17:32 CET | markus.moritz | Entered irradiation information. |
27. Oct 2016 12:05:03 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:31 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:41:04 CEST | Tobias | Imported from Hamamatsu datasheet. |