RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1307014019 - Archived data from Tue, 08. March 2022 14:29:14 CET


This is all the information about APD 1307014019. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1307014019
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B04
Break-through voltage: 442.4 V
Voltage for Gain 100 (T=+25°C): 414.4 V
Dark current: 5.47 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 327
Position in Box: 43
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 309
Position in grid: 16
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 414.7364068 V     T = -25 °C: 378.6065119 V
Voltage for Gain 150: T = +20 °C: 422.7377173 V     T = -25 °C: 386.4512477 V
Voltage for Gain 200: T = +20 °C: 427.1818431 V     T = -25 °C: 390.8013541 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.283188345 V-1     T = -25 °C: 4.417306331 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.104710098 V-1     T = -25 °C: 8.649632092 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.12020358 V-1     T = -25 °C: 15.11486872 V-1
Break-through voltage: T = +20 °C: 442.3845636 V     T = -25 °C: 406.7284437 V
   
Notes:


Version history

Time Author Change comment
28. Jul 2022 13:18:02 CEST oafedulidis Updated box and position via API.
28. Jul 2022 13:15:18 CEST oafedulidis Updated APD location via API.
08. Mar 2022 14:29:14 CET oafedulidis Updated APD characteristics via API.
08. Mar 2022 13:53:28 CET oafedulidis Updated APD batch assignment via API.
22. Feb 2022 10:42:35 CET oafedulidis Updated APD location via API.
22. Feb 2022 10:42:18 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:58:40 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:30:20 CET jreher Updated box and position via API.
07. Oct 2020 15:45:24 CEST jreher Updated APD location via API.
11. Aug 2020 17:53:29 CEST jreher Updated APD location via API.
21. Jul 2020 16:26:36 CEST jreher Updated APD batch assignment via API.
01. Aug 2016 17:28:30 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:41:03 CEST Tobias Imported from Hamamatsu datasheet.