Show Hamamatsu Avalanche Photo Diode 1305013878 - Archived data from Thu, 13. June 2019 11:29:28 CEST
This is all the information about APD 1305013878. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1305013878 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum, Box 35 |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F08 |
Break-through voltage: | 437.9 V |
Voltage for Gain 100 (T=+25°C): | 410.3 V |
Dark current: | 7.12 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 35 |
Position in Box: | 13 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 338 |
Position in grid: | 0 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | 03. Jan 2019 |
Return for assembly: | none |
Irradiation: | |
Date: | 05. Dec 2018 |
Dose used: | 37 Gy |
Temperature: | 20 °C |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | 10. Dec 2018 |
Temperature: | 80 °C |
Duration: | 48 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 10:52:24 CET | jreher | Updated box and position via API. |
03. Feb 2021 18:18:27 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:45:55 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:25:21 CEST | jreher | Updated APD characteristics via API. |
28. Nov 2019 12:22:48 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:13:37 CET | jreher | Updated box and position via API. |
13. Jun 2019 11:29:28 CEST | jreher | Updated APD location via API. |
12. Jun 2019 16:48:00 CEST | jreher | Updated APD batch assignment via API. |
12. Jun 2019 16:32:56 CEST | jreher | Updated APD batch assignment via API. |
03. Jan 2019 13:18:04 CET | markus.moritz | |
29. Sep 2017 10:21:51 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:49 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:40:59 CEST | Tobias | Imported from Hamamatsu datasheet. |