Show Hamamatsu Avalanche Photo Diode 1305013864 - Archived data from Tue, 11. August 2020 17:40:26 CEST
This is all the information about APD 1305013864. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1305013864 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | G06 |
Break-through voltage: | 439.4 V |
Voltage for Gain 100 (T=+25°C): | 411 V |
Dark current: | 7.89 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 290 |
Position in Box: | 45 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 301 |
Position in grid: | 15 |
Arrival for irradiation: | 27. Oct 2016 |
Sent for analysis after irradiation: | 02. Nov 2016 |
Return for assembly: | 29. Nov 2016 |
Irradiation: | |
Date: | 31. Oct 2016 |
Dose used: | 30 Gy |
Temperature: | 20 °C |
Position: | 1 |
Bias voltage: | 350 V (connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 411.3848819 V T = -25 °C: 374.9115635 V |
Voltage for Gain 150: | T = +20 °C: 419.3348119 V T = -25 °C: 382.7508257 V |
Voltage for Gain 200: | T = +20 °C: 423.7475211 V T = -25 °C: 387.0930255 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.441991886 V-1 T = -25 °C: 4.653655587 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.601197435 V-1 T = -25 °C: 9.231431951 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.91301148 V-1 T = -25 °C: 14.44283321 V-1 |
Break-through voltage: | T = +20 °C: 438.0756848 V T = -25 °C: 403.0919966 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:45 CET | jreher | Updated box and position via API. |
11. Aug 2020 17:40:26 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:40:43 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:18:51 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:30 CET | jreher | Updated box and position via API. |
22. Oct 2019 14:32:01 CEST | spankonin | Updated APD location via API. |
15. Oct 2019 11:02:54 CEST | jgrochowski | Updated APD batch assignment via API. |
29. Nov 2016 11:53:51 CET | markus.moritz | Entered return for assembly date. |
02. Nov 2016 14:31:59 CET | markus.moritz | Entered shipped after irradiation date. |
02. Nov 2016 14:29:36 CET | markus.moritz | Entered shipped after irradiation date. |
31. Oct 2016 11:49:32 CET | markus.moritz | Entered irradiation information. |
27. Oct 2016 12:06:58 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:25 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:40:59 CEST | Tobias | Imported from Hamamatsu datasheet. |