Show Hamamatsu Avalanche Photo Diode 1305013858 - Archived data from Fri, 16. April 2021 22:01:11 CEST
This is all the information about APD 1305013858. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1305013858 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | Bochum |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F11 |
Break-through voltage: | 443.1 V |
Voltage for Gain 100 (T=+25°C): | 415.3 V |
Dark current: | 8.93 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 357 |
Position in Box: | 43 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 301 |
Position in grid: | 10 |
Arrival for irradiation: | 27. Oct 2016 |
Sent for analysis after irradiation: | 02. Nov 2016 |
Return for assembly: | 29. Nov 2016 |
Irradiation: | |
Date: | 31. Oct 2016 |
Dose used: | 30 Gy |
Temperature: | 20 °C |
Position: | 1 |
Bias voltage: | 350 V (not connected) |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 415.7524018 V T = -25 °C: 378.9717233 V |
Voltage for Gain 150: | T = +20 °C: 423.6182607 V T = -25 °C: 386.80354 V |
Voltage for Gain 200: | T = +20 °C: 427.9804706 V T = -25 °C: 391.1862487 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.667193427 V-1 T = -25 °C: 4.602963243 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 9.220100068 V-1 T = -25 °C: 8.995217194 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 14.376687 V-1 T = -25 °C: 13.96882335 V-1 |
Break-through voltage: | T = +20 °C: 439.9523896 V T = -25 °C: 406.8806839 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
21. Apr 2021 14:45:24 CEST | oafedulidis | Updated box and position via API. |
16. Apr 2021 22:01:11 CEST | jreher | Updated APD characteristics via API. |
05. Feb 2021 11:34:08 CET | jreher | Updated box and position via API. |
08. Oct 2020 18:15:37 CEST | jreher | Updated APD location via API. |
17. Aug 2020 14:32:47 CEST | vwerner | Updated APD batch assignment via API. |
29. Nov 2016 11:53:51 CET | markus.moritz | Entered return for assembly date. |
02. Nov 2016 14:31:59 CET | markus.moritz | Entered shipped after irradiation date. |
02. Nov 2016 14:29:36 CET | markus.moritz | Entered shipped after irradiation date. |
31. Oct 2016 11:49:32 CET | markus.moritz | Entered irradiation information. |
27. Oct 2016 12:06:58 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:25 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:40:59 CEST | Tobias | Imported from Hamamatsu datasheet. |