RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1304013777 - Archived data from Thu, 06. October 2016 09:44:15 CEST


This is all the information about APD 1304013777. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1304013777
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: B05
Break-through voltage: 445 V
Voltage for Gain 100 (T=+25°C): 416.1 V
Dark current: 8.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 374
Position in Box: 10
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 298
Position in grid: 13
Arrival for irradiation: 11. Aug 2016
Sent for analysis after irradiation: 02. Sep 2016
Return for assembly: 06. Oct 2016
   
Irradiation:  
Date: 23. Aug 2016
Dose used: 30 Gy
Temperature: 25 °C
Position: 1
Bias voltage: 350 V     (connected)
   
Annealing:  
Date: 24. Aug 2016
Temperature: 80 °C
Duration: 10 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
16. Apr 2021 22:02:38 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:36:18 CET jreher Updated box and position via API.
08. Oct 2020 18:18:50 CEST jreher Updated APD location via API.
28. Sep 2020 14:23:57 CEST vwerner Updated APD batch assignment via API.
06. Oct 2016 09:44:15 CEST markus.moritz Entered return for assembly date.
08. Sep 2016 13:35:37 CEST markus.moritz Entered shipped after irradiation date.
24. Aug 2016 14:40:03 CEST christopher.l.hahn Entered irradiation information.
24. Aug 2016 14:23:22 CEST christopher.l.hahn Entered annealing information.
11. Aug 2016 11:46:07 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:23 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:39:47 CEST Tobias Imported from Hamamatsu datasheet.