RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1303013740 - Archived data from Wed, 10. November 2021 14:36:08 CET


This is all the information about APD 1303013740. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1303013740
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: In transit to Mainz
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: G07
Break-through voltage: 437 V
Voltage for Gain 100 (T=+25°C): 408.6 V
Dark current: 7.4 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 336
Position in Box: 43
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 296
Position in grid: 4
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 408.8438936 V     T = -25 °C: 372.0872177 V
Voltage for Gain 150: T = +20 °C: 416.7715751 V     T = -25 °C: 379.9763538 V
Voltage for Gain 200: T = +20 °C: 421.1493023 V     T = -25 °C: 384.3610502 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.63193372 V-1     T = -25 °C: 4.587962847 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 9.248545166 V-1     T = -25 °C: 9.073397808 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 14.52920532 V-1     T = -25 °C: 14.13798725 V-1
Break-through voltage: T = +20 °C: 436.4788978 V     T = -25 °C: 400.1362744 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:35 CET jreher Updated APD characteristics via API.
10. Nov 2021 14:36:21 CET oafedulidis Updated APD location via API.
10. Nov 2021 14:36:08 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:58:13 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:31:23 CET jreher Updated box and position via API.
07. Oct 2020 15:45:38 CEST jreher Updated APD location via API.
11. Aug 2020 17:53:43 CEST jreher Updated APD location via API.
21. Jul 2020 16:17:26 CEST jreher Updated APD batch assignment via API.
01. Aug 2016 17:28:21 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:39:46 CEST Tobias Imported from Hamamatsu datasheet.