Show Hamamatsu Avalanche Photo Diode 1302013717 - Archived data from Mon, 14. October 2019 17:31:22 CEST
This is all the information about APD 1302013717. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1302013717 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | unknown |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | F04 |
Break-through voltage: | 441 V |
Voltage for Gain 100 (T=+25°C): | 412.2 V |
Dark current: | 7.9 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 289 |
Position in Box: | 42 |
EP1 batch: | none |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 295 |
Position in grid: | 1 |
Arrival for irradiation: | 11. Jul 2016 |
Sent for analysis after irradiation: | 15. Jul 2016 |
Return for assembly: | 19. Sep 2016 |
Irradiation: | |
Date: | 13. Jul 2016 |
Dose used: | 30 Gy |
Temperature: | 25 °C |
Position: | 3 |
Bias voltage: | 320 V (connection unknown) |
Annealing: | |
Date: | 13. Jul 2016 |
Temperature: | 80 °C |
Duration: | 10 h |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 150: | T = +20 °C: none T = -25 °C: none |
Voltage for Gain 200: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 100: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 150: | T = +20 °C: none T = -25 °C: none |
Gain/Voltage slope at M = 200: | T = +20 °C: none T = -25 °C: none |
Break-through voltage: | T = +20 °C: none T = -25 °C: none |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:25:37 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:50 CEST | jreher | Updated APD location via API. |
11. Aug 2020 17:40:15 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:40:33 CEST | jreher | Updated box and position via API. |
27. Nov 2019 20:18:40 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:25 CET | jreher | Updated box and position via API. |
22. Oct 2019 14:31:16 CEST | spankonin | Updated APD location via API. |
14. Oct 2019 17:31:22 CEST | jgrochowski | Updated APD batch assignment via API. |
23. Sep 2016 09:04:48 CEST | markus.moritz | Entered return for assembly date. |
03. Aug 2016 16:34:45 CEST | markus.moritz | Entered irradiation information. |
02. Aug 2016 14:59:30 CEST | christopher.l.hahn | Entered annealing information. |
02. Aug 2016 10:48:22 CEST | markus.moritz | Entered shipped after irradiation date. |
02. Aug 2016 10:45:53 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:20 CEST | Tobias | Assigned to grid via information extracted from APD DB. |
22. Jun 2016 15:39:46 CEST | Tobias | Imported from Hamamatsu datasheet. |