RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1302013717 - Archived data from Tue, 02. August 2016 14:59:30 CEST


This is all the information about APD 1302013717. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1302013717
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: unknown
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F04
Break-through voltage: 441 V
Voltage for Gain 100 (T=+25°C): 412.2 V
Dark current: 7.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 289
Position in Box: 42
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 295
Position in grid: 1
Arrival for irradiation: 11. Jul 2016
Sent for analysis after irradiation: 15. Jul 2016
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: 13. Jul 2016
Temperature: 80 °C
Duration: 10 h
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 150: T = +20 °C: none     T = -25 °C: none
Voltage for Gain 200: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 100: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 150: T = +20 °C: none     T = -25 °C: none
Gain/Voltage slope at M = 200: T = +20 °C: none     T = -25 °C: none
Break-through voltage: T = +20 °C: none     T = -25 °C: none
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:25:37 CET jreher Updated box and position via API.
07. Oct 2020 15:44:50 CEST jreher Updated APD location via API.
11. Aug 2020 17:40:15 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:40:33 CEST jreher Updated box and position via API.
27. Nov 2019 20:18:40 CET jreher Updated APD location via API.
25. Nov 2019 17:31:25 CET jreher Updated box and position via API.
22. Oct 2019 14:31:16 CEST spankonin Updated APD location via API.
14. Oct 2019 17:31:22 CEST jgrochowski Updated APD batch assignment via API.
23. Sep 2016 09:04:48 CEST markus.moritz Entered return for assembly date.
03. Aug 2016 16:34:45 CEST markus.moritz Entered irradiation information.
02. Aug 2016 14:59:30 CEST christopher.l.hahn Entered annealing information.
02. Aug 2016 10:48:22 CEST markus.moritz Entered shipped after irradiation date.
02. Aug 2016 10:45:53 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:20 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:39:46 CEST Tobias Imported from Hamamatsu datasheet.