Show Hamamatsu Avalanche Photo Diode 1302013677 - Archived data from Wed, 07. October 2020 15:44:40 CEST
This is all the information about APD 1302013677. If it is wrong, edit the data.
Subdetector specification: | |
---|---|
Serial: | 1302013677 |
Type: | Hamamatsu Avalanche Photo Diode |
Detector: | unassigned |
Unit: | unassigned |
Preamp: | 0 |
Current location: | In transit to Mainz |
Installation information: | |
Label: | none |
Manufacturer information: | |
Wafer position: | A07 |
Break-through voltage: | 446 V |
Voltage for Gain 100 (T=+25°C): | 417.2 V |
Dark current: | 4.7 nA |
Screening Logistics: | |
Available: | Yes |
Storage Box: | 284 |
Position in Box: | 29 |
EP1 batch: | 202 |
EP1 batch after irradiation: | none |
Shipment: | |
Grid number: | 293 |
Position in grid: | 5 |
Arrival for irradiation: | 29. Sep 2017 |
Sent for analysis after irradiation: | none |
Return for assembly: | none |
Irradiation: | |
Date: | none |
Dose used: | none |
Temperature: | none |
Position: | none |
Bias voltage: | none |
Annealing: | |
Date: | none |
Temperature: | none |
Duration: | none |
Measurement results: | |
Voltage for Gain 100: | T = +20 °C: 417.064687 V T = -25 °C: 380.6241561 V |
Voltage for Gain 150: | T = +20 °C: 425.0614219 V T = -25 °C: 388.5636909 V |
Voltage for Gain 200: | T = +20 °C: 429.508187 V T = -25 °C: 392.9678323 V |
Gain/Voltage slope at M = 100: | T = +20 °C: 4.478908352 V-1 T = -25 °C: 4.333143346 V-1 |
Gain/Voltage slope at M = 150: | T = +20 °C: 8.72540147 V-1 T = -25 °C: 9.236632341 V-1 |
Gain/Voltage slope at M = 200: | T = +20 °C: 15.13707228 V-1 T = -25 °C: 14.32630843 V-1 |
Break-through voltage: | T = +20 °C: 439.967189 V T = -25 °C: 409.1862428 V |
Notes: |
Version history
Time | Author | Change comment |
---|---|---|
05. Feb 2021 11:24:59 CET | jreher | Updated box and position via API. |
07. Oct 2020 15:44:40 CEST | jreher | Updated APD location via API. |
11. Aug 2020 18:03:54 CEST | jreher | Updated APD characteristics via API. |
21. Jul 2020 14:39:39 CEST | jreher | Updated APD location via API. |
21. Jul 2020 14:39:29 CEST | jreher | Updated box and position via API. |
10. Feb 2020 18:58:27 CET | spankonin | Updated APD batch assignment via API. |
29. Nov 2019 11:50:11 CET | jreher | Updated APD location via API. |
27. Nov 2019 20:17:48 CET | jreher | Updated APD location via API. |
25. Nov 2019 17:31:01 CET | jreher | Updated box and position via API. |
22. Oct 2019 13:10:00 CEST | spankonin | Updated APD location via API. |
09. Oct 2019 11:41:28 CEST | jgrochowski | Updated APD batch assignment via API. |
29. Sep 2017 12:03:34 CEST | markus.moritz | Entered arrival for irradiation date. |
01. Aug 2016 17:28:19 CEST | Tobias | Assigned to grid via information extracted from APD DB. |