RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1302013677 - Archived data from Tue, 11. August 2020 18:03:54 CEST


This is all the information about APD 1302013677. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1302013677
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A07
Break-through voltage: 446 V
Voltage for Gain 100 (T=+25°C): 417.2 V
Dark current: 4.7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 284
Position in Box: 29
EP1 batch: 202
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 293
Position in grid: 5
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 417.064687 V     T = -25 °C: 380.6241561 V
Voltage for Gain 150: T = +20 °C: 425.0614219 V     T = -25 °C: 388.5636909 V
Voltage for Gain 200: T = +20 °C: 429.508187 V     T = -25 °C: 392.9678323 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.478908352 V-1     T = -25 °C: 4.333143346 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.72540147 V-1     T = -25 °C: 9.236632341 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 15.13707228 V-1     T = -25 °C: 14.32630843 V-1
Break-through voltage: T = +20 °C: 439.967189 V     T = -25 °C: 409.1862428 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:59 CET jreher Updated box and position via API.
07. Oct 2020 15:44:40 CEST jreher Updated APD location via API.
11. Aug 2020 18:03:54 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:39 CEST jreher Updated APD location via API.
21. Jul 2020 14:39:29 CEST jreher Updated box and position via API.
10. Feb 2020 18:58:27 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:11 CET jreher Updated APD location via API.
27. Nov 2019 20:17:48 CET jreher Updated APD location via API.
25. Nov 2019 17:31:01 CET jreher Updated box and position via API.
22. Oct 2019 13:10:00 CEST spankonin Updated APD location via API.
09. Oct 2019 11:41:28 CEST jgrochowski Updated APD batch assignment via API.
29. Sep 2017 12:03:34 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:19 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:39:45 CEST Tobias Imported from Hamamatsu datasheet.