Subdetector specification:  
Serial: 1302013676
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F08
Break-through voltage: 441 V
Voltage for Gain 100 (T=+25°C): 412.2 V
Dark current: 7.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 284
Position in Box: 28
EP1 batch: 202
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 293
Position in grid: 4
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 411.9898069 V     T = -25 °C: 375.2759013 V
Voltage for Gain 150: T = +20 °C: 419.9882481 V     T = -25 °C: 383.206084 V
Voltage for Gain 200: T = +20 °C: 424.4343063 V     T = -25 °C: 387.6138104 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.504172157 V-1     T = -25 °C: 4.453629048 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.857192485 V-1     T = -25 °C: 8.726704725 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.66993214 V-1     T = -25 °C: 15.22462675 V-1
Break-through voltage: T = +20 °C: 439.768077 V     T = -25 °C: 403.4707216 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:24:58 CET jreher Updated box and position via API.
07. Oct 2020 15:44:39 CEST jreher Updated APD location via API.
11. Aug 2020 18:03:53 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:39:39 CEST jreher Updated APD location via API.
21. Jul 2020 14:39:29 CEST jreher Updated box and position via API.
10. Feb 2020 18:58:27 CET spankonin Updated APD batch assignment via API.
29. Nov 2019 11:50:11 CET jreher Updated APD location via API.
27. Nov 2019 20:17:48 CET jreher Updated APD location via API.
25. Nov 2019 17:31:01 CET jreher Updated box and position via API.
22. Oct 2019 13:10:00 CEST spankonin Updated APD location via API.
09. Oct 2019 11:41:28 CEST jgrochowski Updated APD batch assignment via API.
29. Sep 2017 12:03:33 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:19 CEST Tobias Assigned to grid via information extracted from APD DB.