RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1301013601 - Archived data from Tue, 11. August 2020 18:09:07 CEST


This is all the information about APD 1301013601. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1301013601
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: F11
Break-through voltage: 442 V
Voltage for Gain 100 (T=+25°C): 414 V
Dark current: 8.5 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 267
Position in Box: 49
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 290
Position in grid: 2
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 434.4578121 V     T = -25 °C: 373.7860806 V
Voltage for Gain 150: T = +20 °C: 437.1680705 V     T = -25 °C: 379.8200524 V
Voltage for Gain 200: T = +20 °C: 437.75533 V     T = -25 °C: 390.713621 V
Gain/Voltage slope at M = 100: T = +20 °C: 12.07763369 V-1     T = -25 °C: 178.584467 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 28.88626647 V-1     T = -25 °C: 81.51832442 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 28.88626647 V-1     T = -25 °C: 132.396325 V-1
Break-through voltage: T = +20 °C: 437.2066961 V     T = -25 °C: 405.4053291 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:17 CET jreher Updated APD characteristics via API.
10. Nov 2021 14:34:47 CET oafedulidis Updated APD location via API.
10. Nov 2021 14:34:32 CET oafedulidis Updated APD batch assignment via API.
05. Feb 2021 11:22:48 CET jreher Updated box and position via API.
07. Oct 2020 15:44:37 CEST jreher Updated APD location via API.
11. Aug 2020 18:09:07 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:35:45 CEST jreher Updated APD location via API.
21. Jul 2020 14:35:36 CEST jreher Updated box and position via API.
29. Jun 2020 16:10:18 CEST jreher Updated APD batch assignment via API.
01. Aug 2016 17:28:17 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:39:43 CEST Tobias Imported from Hamamatsu datasheet.