RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1210013434 - Archived data from Tue, 11. August 2020 17:57:48 CEST


This is all the information about APD 1210013434. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1210013434
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: A06
Break-through voltage: 440 V
Voltage for Gain 100 (T=+25°C): 412 V
Dark current: 7 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 304
Position in Box: 6
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 283
Position in grid: 19
Arrival for irradiation: 29. Sep 2017
Sent for analysis after irradiation: 27. Oct 2017
Return for assembly: none
   
Irradiation:  
Date: 25. Oct 2017
Dose used: 45 Gy
Temperature: 20 °C
Position: 2
Bias voltage: 412 V     (connected)
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 412.0310608 V     T = -25 °C: 375.2471776 V
Voltage for Gain 150: T = +20 °C: 420.0026054 V     T = -25 °C: 383.1672982 V
Voltage for Gain 200: T = +20 °C: 424.442791 V     T = -25 °C: 387.5740419 V
Gain/Voltage slope at M = 100: T = +20 °C: 4.521322105 V-1     T = -25 °C: 4.473258996 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 8.861170271 V-1     T = -25 °C: 8.781405669 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 13.71424046 V-1     T = -25 °C: 15.26724423 V-1
Break-through voltage: T = +20 °C: 439.2599685 V     T = -25 °C: 403.1695662 V
   
Notes:


Version history

Time Author Change comment
05. Feb 2021 11:27:30 CET jreher Updated box and position via API.
07. Oct 2020 15:45:05 CEST jreher Updated APD location via API.
11. Aug 2020 17:57:48 CEST jreher Updated APD characteristics via API.
21. Jul 2020 14:43:54 CEST jreher Updated APD location via API.
21. Jul 2020 14:43:45 CEST jreher Updated box and position via API.
19. Dec 2019 16:19:58 CET spankonin Updated APD batch assignment via API.
19. Dec 2019 15:18:20 CET jreher Updated box and position via API.
27. Oct 2017 10:38:00 CEST markus.moritz Entered shipped after irradiation date.
26. Oct 2017 16:27:14 CEST markus.moritz Entered irradiation information.
29. Sep 2017 14:19:28 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:13 CEST Tobias Assigned to grid via information extracted from APD DB.