RUB » Physics » The Faculty » Chairs and Working Groups » EP1 » PANDA FEMC Production Database

Show Hamamatsu Avalanche Photo Diode 1209013348 - Archived data from Mon, 15. November 2021 16:06:01 CET


This is all the information about APD 1209013348. If it is wrong, edit the data.

Subdetector specification:  
Serial: 1209013348
Type: Hamamatsu Avalanche Photo Diode
Detector: unassigned
Unit: unassigned
Preamp: 0
Current location: Bochum
   
Installation information:  
Label: none
   
Manufacturer information:  
Wafer position: C03
Break-through voltage: 451 V
Voltage for Gain 100 (T=+25°C): 421.9 V
Dark current: 7.9 nA
   
Screening Logistics:  
Available: Yes
Storage Box: 338
Position in Box: 35
EP1 batch: none
EP1 batch after irradiation: none
   
Shipment:  
Grid number: 279
Position in grid: 19
Arrival for irradiation: none
Sent for analysis after irradiation: none
Return for assembly: none
   
Irradiation:  
Date: none
Dose used: none
Temperature: none
Position: none
Bias voltage: none     
   
Annealing:  
Date: none
Temperature: none
Duration: none
   
Measurement results:  
Voltage for Gain 100: T = +20 °C: 439.2253945 V     T = -25 °C: 379.6045826 V
Voltage for Gain 150: T = +20 °C: 439.2253945 V     T = -25 °C: 385.6405549 V
Voltage for Gain 200: T = +20 °C: 439.2253945 V     T = -25 °C: 394.4970757 V
Gain/Voltage slope at M = 100: T = +20 °C: 6.437169128 V-1     T = -25 °C: 49.57673348 V-1
Gain/Voltage slope at M = 150: T = +20 °C: 6.437169128 V-1     T = -25 °C: 49.44739992 V-1
Gain/Voltage slope at M = 200: T = +20 °C: 6.437169128 V-1     T = -25 °C: 46.36436553 V-1
Break-through voltage: T = +20 °C: 439.4071675 V     T = -25 °C: 413.8992205 V
   
Notes:


Version history

Time Author Change comment
07. Feb 2022 16:17:42 CET jreher Updated APD characteristics via API.
15. Nov 2021 16:06:01 CET oafedulidis Updated APD location via API.
15. Nov 2021 16:05:43 CET oafedulidis Updated APD batch assignment via API.
16. Apr 2021 21:59:06 CEST jreher Updated APD characteristics via API.
05. Feb 2021 11:31:37 CET jreher Updated box and position via API.
07. Oct 2020 15:45:43 CEST jreher Updated APD location via API.
11. Aug 2020 17:53:50 CEST jreher Updated APD location via API.
03. Aug 2020 16:57:14 CEST jreher Updated APD batch assignment via API.
27. Oct 2017 10:23:25 CEST Tobias Resetted arrival for irradiation date as APDs are returned to GSI un-irradiated.
29. Sep 2017 12:28:59 CEST markus.moritz Entered arrival for irradiation date.
01. Aug 2016 17:28:10 CEST Tobias Assigned to grid via information extracted from APD DB.
22. Jun 2016 15:39:37 CEST Tobias Imported from Hamamatsu datasheet.